The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account.
Max CVSS
8.0
EPSS Score
0.21%
Published
2013-12-17
Updated
2022-02-01
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value.
Max CVSS
8.3
EPSS Score
0.30%
Published
2013-12-17
Updated
2022-02-01
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
Max CVSS
10.0
EPSS Score
0.69%
Published
2013-12-07
Updated
2020-02-10
Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors.
Max CVSS
6.9
EPSS Score
0.04%
Published
2013-12-10
Updated
2013-12-12
The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.
Max CVSS
10.0
EPSS Score
0.53%
Published
2013-10-03
Updated
2020-02-10
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value.
Max CVSS
8.3
EPSS Score
0.72%
Published
2013-09-17
Updated
2020-02-10
The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access.
Max CVSS
7.2
EPSS Score
0.04%
Published
2013-08-09
Updated
2013-08-13
Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
Max CVSS
5.8
EPSS Score
0.39%
Published
2013-08-01
Updated
2017-08-29
Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
Max CVSS
6.8
EPSS Score
0.31%
Published
2013-08-01
Updated
2017-08-29
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to execute arbitrary commands via unspecified vectors.
Max CVSS
10.0
EPSS Score
0.29%
Published
2013-07-18
Updated
2013-08-22
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to read arbitrary files via unspecified vectors.
Max CVSS
7.8
EPSS Score
0.32%
Published
2013-07-18
Updated
2013-08-22
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Max CVSS
4.3
EPSS Score
0.14%
Published
2013-07-18
Updated
2013-08-22
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to obtain sensitive server and statistics information via unspecified vectors.
Max CVSS
7.8
EPSS Score
0.32%
Published
2013-07-18
Updated
2013-08-22
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
Max CVSS
10.0
EPSS Score
0.32%
Published
2013-08-01
Updated
2013-08-01
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
Max CVSS
6.6
EPSS Score
0.17%
Published
2013-08-01
Updated
2013-08-01
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
Max CVSS
4.0
EPSS Score
0.10%
Published
2013-06-14
Updated
2013-06-17
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.
Max CVSS
7.5
EPSS Score
0.30%
Published
2013-06-14
Updated
2013-06-17
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Max CVSS
7.5
EPSS Score
0.10%
Published
2013-06-14
Updated
2013-06-17
Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access.
Max CVSS
4.6
EPSS Score
0.04%
Published
2013-06-18
Updated
2013-06-19
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.
Max CVSS
7.5
EPSS Score
0.17%
Published
2013-05-24
Updated
2019-12-12
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The user privileges for the web interface are only enforced on client side and not properly verified on server side. Therefore, an attacker is able to execute privileged commands using an unprivileged account.
Max CVSS
8.0
EPSS Score
0.09%
Published
2013-05-24
Updated
2019-12-12
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
Max CVSS
7.8
EPSS Score
0.26%
Published
2013-04-22
Updated
2022-02-01
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
Max CVSS
7.8
EPSS Score
0.26%
Published
2013-04-22
Updated
2022-02-01
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Max CVSS
4.0
EPSS Score
0.08%
Published
2013-03-21
Updated
2013-03-22
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.
Max CVSS
4.0
EPSS Score
0.12%
Published
2013-03-21
Updated
2013-03-22
38 vulnerabilities found