Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.
Max CVSS
10.0
EPSS Score
5.25%
Published
2008-09-29
Updated
2018-10-11
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.
Max CVSS
10.0
EPSS Score
13.22%
Published
2012-03-09
Updated
2012-10-30
Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data.
Max CVSS
7.7
EPSS Score
0.86%
Published
2012-04-18
Updated
2017-12-20
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Max CVSS
9.3
EPSS Score
89.80%
Published
2013-08-06
Updated
2013-09-18
Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program.
Max CVSS
6.9
EPSS Score
0.05%
Published
2014-11-07
Updated
2014-11-07
Untrusted search path vulnerability in ABB Panel Builder 800 5.1 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
Max CVSS
7.2
EPSS Score
0.05%
Published
2016-03-18
Updated
2016-03-21
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file.
Max CVSS
2.8
EPSS Score
0.04%
Published
2016-06-10
Updated
2016-06-17
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors.
Max CVSS
3.3
EPSS Score
0.04%
Published
2016-06-10
Updated
2016-06-15
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.
Max CVSS
6.5
EPSS Score
0.04%
Published
2016-06-10
Updated
2016-06-15
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors.
Max CVSS
3.3
EPSS Score
0.04%
Published
2016-06-10
Updated
2016-06-15
In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.
Max CVSS
8.8
EPSS Score
0.09%
Published
2018-06-06
Updated
2019-10-09
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
Max CVSS
6.5
EPSS Score
0.11%
Published
2017-08-07
Updated
2019-10-09
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
Max CVSS
7.5
EPSS Score
0.16%
Published
2017-08-07
Updated
2019-10-09
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
Max CVSS
9.8
EPSS Score
0.20%
Published
2018-06-06
Updated
2019-10-09
In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.
Max CVSS
9.8
EPSS Score
0.21%
Published
2018-06-06
Updated
2019-10-03
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization.
Max CVSS
9.8
EPSS Score
0.20%
Published
2018-05-24
Updated
2019-10-09
An Information Exposure issue was discovered in ABB netCADOPS Web Application Version 3.4 and prior, netCADOPS Web Application Version 7.1 and prior, netCADOPS Web Application Version 7.2x and prior, netCADOPS Web Application Version 8.0 and prior, and netCADOPS Web Application Version 8.1 and prior. A vulnerability exists in the password entry section of netCADOPS Web Application that may expose critical database information.
Max CVSS
5.8
EPSS Score
0.06%
Published
2018-02-20
Updated
2019-10-09
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.
Max CVSS
9.3
EPSS Score
2.06%
Published
2018-07-18
Updated
2019-10-09
The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism.
Max CVSS
4.3
EPSS Score
0.05%
Published
2019-01-31
Updated
2019-10-09
The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing the user authentication mechanism.
Max CVSS
6.5
EPSS Score
0.05%
Published
2019-01-31
Updated
2019-10-09
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
Max CVSS
9.8
EPSS Score
0.18%
Published
2019-01-03
Updated
2019-10-09
Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser.
Max CVSS
6.1
EPSS Score
0.08%
Published
2019-01-03
Updated
2019-10-09
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
Max CVSS
7.8
EPSS Score
0.10%
Published
2019-02-13
Updated
2019-10-09
The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 password for the IdalMaster account, and the exor password for the exor account. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials. An attacker can use these credentials to login to ABB HMI to read/write HMI configuration files and also to reset the device. This affects ABB CP635 HMI, CP600 HMIClient, Panel Builder 600, IDAL FTP server, IDAL HTTP server, and multiple other HMI components.
Max CVSS
8.8
EPSS Score
0.21%
Published
2019-06-27
Updated
2023-05-16
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
Max CVSS
8.8
EPSS Score
0.30%
Published
2019-06-27
Updated
2022-11-30
121 vulnerabilities found