A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Max CVSS
3.3
EPSS Score
0.04%
Published
2024-04-09
Updated
2024-04-09
A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
Max CVSS
3.3
EPSS Score
0.04%
Published
2024-04-09
Updated
2024-04-09
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.251), Parasolid V35.1 (All versions < V35.1.170). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XT files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Max CVSS
3.3
EPSS Score
0.04%
Published
2024-02-13
Updated
2024-02-13
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.
Max CVSS
2.7
EPSS Score
0.04%
Published
2023-12-12
Updated
2023-12-14
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.
Max CVSS
2.7
EPSS Score
0.04%
Published
2023-12-12
Updated
2023-12-14
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.
Max CVSS
3.9
EPSS Score
N/A
Published
2023-09-12
Updated
2023-09-14
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.
Max CVSS
3.8
EPSS Score
0.06%
Published
2023-05-09
Updated
2023-05-15
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will crash if supplied with a backup password longer than 255 characters. This could allow an authenticated privileged attacker to cause a denial of service.
Max CVSS
2.7
EPSS Score
0.04%
Published
2023-05-09
Updated
2023-05-15
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read the contents of any file named `address`.
Max CVSS
3.3
EPSS Score
0.04%
Published
2023-05-09
Updated
2023-05-15
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The `i2c` mutex file is created with the permissions bits of `-rw-rw-rw-`. This file is used as a mutex for multiple applications interacting with i2c. This could allow an authenticated attacker with access to the SSH interface on the affected device to interfere with the integrity of the mutex and the data it protects.
Max CVSS
3.3
EPSS Score
0.04%
Published
2023-05-09
Updated
2023-05-15
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.
Max CVSS
2.7
EPSS Score
0.05%
Published
2022-12-13
Updated
2023-12-12
curl 7.7 through 7.76.1 suffers from an information disclosure when the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl, is used to send variable=content pairs to TELNET servers. Due to a flaw in the option parser for sending NEW_ENV variables, libcurl could be made to pass on uninitialized data from a stack based buffer to the server, resulting in potentially revealing sensitive internal information to the server using a clear-text network protocol.
Max CVSS
3.1
EPSS Score
0.20%
Published
2021-06-11
Updated
2024-03-27
The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.
Max CVSS
3.5
EPSS Score
0.21%
Published
2021-05-11
Updated
2023-04-01
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
Max CVSS
2.5
EPSS Score
0.04%
Published
2016-10-13
Updated
2016-12-22
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage.
Max CVSS
2.5
EPSS Score
0.04%
Published
2016-07-04
Updated
2023-10-17
Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors.
Max CVSS
3.6
EPSS Score
0.04%
Published
2016-03-18
Updated
2016-12-03
Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame.
Max CVSS
3.3
EPSS Score
0.25%
Published
2015-10-28
Updated
2017-09-15
The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors.
Max CVSS
2.1
EPSS Score
0.10%
Published
2015-08-03
Updated
2017-09-21
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files.
Max CVSS
2.1
EPSS Score
0.04%
Published
2015-04-06
Updated
2015-04-23
The Siemens SPCanywhere application for iOS allows physically proximate attackers to bypass intended access restrictions by leveraging a filesystem architectural error.
Max CVSS
2.1
EPSS Score
0.04%
Published
2015-03-07
Updated
2015-03-09
The Siemens SPCanywhere application for Android does not properly store application passwords, which allows physically proximate attackers to obtain sensitive information by examining the device filesystem.
Max CVSS
2.1
EPSS Score
0.04%
Published
2015-03-07
Updated
2015-03-09
Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack.
Max CVSS
2.1
EPSS Score
0.04%
Published
2015-02-18
Updated
2015-02-18
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism.
Max CVSS
1.9
EPSS Score
0.07%
Published
2015-01-14
Updated
2015-11-13
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state.
Max CVSS
1.9
EPSS Score
0.04%
Published
2015-01-14
Updated
2015-11-13
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors.
Max CVSS