Vulnerability Details : CVE-2013-2811
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
Vulnerability category: Input validationDenial of service
Exploit prediction scoring system (EPSS) score for CVE-2013-2811
Probability of exploitation activity in the next 30 days: 0.64%
Percentile, the proportion of vulnerabilities that are scored at or less: ~ 76 % EPSS Score History EPSS FAQ
CVSS scores for CVE-2013-2811
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source |
---|---|---|---|---|---|
7.1
|
HIGH | AV:N/AC:M/Au:N/C:N/I:N/A:C |
8.6
|
6.9
|
NIST |
CWE ids for CVE-2013-2811
-
The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.Assigned by: nvd@nist.gov (Primary)
References for CVE-2013-2811
-
http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB15805
GE Customer CenterVendor Advisory
-
http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01
Catapult Software DNP3 Driver Improper Input Validation | CISAUS Government Resource
-
http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02
GE Proficy DNP3 Improper Input Validation | CISAUS Government Resource
-
http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf
GE Customer CenterVendor Advisory
Products affected by CVE-2013-2811
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_ifix:5.0:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_ifix:5.1:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:4.01:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.0:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:7.5:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.1:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.2:*:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:*:j:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:i:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:h:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:g:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:f:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:a:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:-:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:d:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:b:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:e:*:*:*:*:*:*
- cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\/o_driver:7.20:c:*:*:*:*:*:*
- cpe:2.3:a:catapultsoftware:catapult_dnp3_i\/o_driver:*:*:*:*:*:*:*:*